Premco Fiber Glass Rebar
MAXIMUM STRENGTH GFRP
Technical Information
Imperial | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | |
Metric | 6 | 10 | 13 | 16 | 20 | 22 | 25 | 29 | 32 | 36 | |
Minimum Tensile Load |
kN | 33 | 74 | 132 | 202 | 285 | 390 | 507 | 650 | 819 | 1000 |
Ibf | 7419 | 16636 | 29675 | 45411 | 64070 | 87675 | 112180 | 146126 | 184118 | 224810 | |
Cross Sectional Area | mm2 | 32 | 71 | 132 | 201 | 285 | 387 | 491 | 645 | 819 | 1007 |
Weight | kg/m | 0.12 | 0.22 | 0.35 | 0.5 | 0.7 | 0.9 | 1.22 | 1.4 | 1.72 | 2.15 |
Guaranteed Tensile Strength |
>1000 MPa >145 Ksi |
Young’s Modulus , E | >60GPa >8702KSI |
Ultimate Strain , εfu | >1.7% |
Transverse Shear Strength , τ |
>220 MPa 31.9 ksi |
Bond Strength to Concrete |
20 MPa Minimum 2900 Psi Minimum |
Strength of Bend (Straight Portion) |
>900 MPa |
Strength of Bend (Bend Portion with Minimum Radius Bend : 4x Diameter of Bar) |
>600 |
Young’s Modulus , E (Bend Bar) |
50 GPa |
Glass Transition Temperature, Tg° |
125C° |
Contact
Call Or whatsapp Us for all your projects need At
Offices
975A Elgin St W, Suite 372, Cobourg, ON, K9A5J3
Follow Us
Copyright © 2024 Premco ®